Update the SP805 binding document to add optional 'timeout-sec' devicetree property
Signed-off-by: Ray Jui <ray....@broadcom.com> Reviewed-by: Scott Branden <scott.bran...@broadcom.com> --- Documentation/devicetree/bindings/watchdog/sp805-wdt.txt | 2 ++ 1 file changed, 2 insertions(+) diff --git a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt index edc4f0e..f898a86 100644 --- a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt +++ b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt @@ -19,6 +19,8 @@ Required properties: Optional properties: - interrupts : Should specify WDT interrupt number. +- timeout-sec : Should specify default WDT timeout in seconds. If unset, the + default timeout is 30 seconds Examples: -- 2.1.4