Update the SP805 binding document to add optional 'timeout-sec'
devicetree property

Signed-off-by: Ray Jui <ray....@broadcom.com>
Reviewed-by: Scott Branden <scott.bran...@broadcom.com>
---
 Documentation/devicetree/bindings/watchdog/sp805-wdt.txt | 2 ++
 1 file changed, 2 insertions(+)

diff --git a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt 
b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
index edc4f0e..f898a86 100644
--- a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
+++ b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
@@ -19,6 +19,8 @@ Required properties:
 
 Optional properties:
 - interrupts : Should specify WDT interrupt number.
+- timeout-sec : Should specify default WDT timeout in seconds. If unset, the
+                default timeout is 30 seconds
 
 Examples:
 
-- 
2.1.4

Reply via email to