For configure low level state of charge threshold alert signaled from
max17040 we add "maxim,alert-soc-level" property.

Signed-off-by: Matheus Castello <math...@castello.eng.br>
---
 .../bindings/power/supply/max17040_battery.txt     | 24 ++++++++++++++++++++++
 1 file changed, 24 insertions(+)
 create mode 100644 
Documentation/devicetree/bindings/power/supply/max17040_battery.txt

diff --git 
a/Documentation/devicetree/bindings/power/supply/max17040_battery.txt 
b/Documentation/devicetree/bindings/power/supply/max17040_battery.txt
new file mode 100644
index 000000000000..e6e4e46c03c4
--- /dev/null
+++ b/Documentation/devicetree/bindings/power/supply/max17040_battery.txt
@@ -0,0 +1,24 @@
+max17040_battery
+~~~~~~~~~~~~~~~~
+
+Required properties :
+ - compatible : "maxim,max17040"
+
+Optional threshold properties :
+ If skipped the power up default value will be used
+ - maxim,alert-soc-level :     The alert threshold that sets the state of
+                               charge level where an interrupt is generated.
+                               max17040 can be configured from 1 up to 32.
+
+Remembering that for the interrupt to be handled it must also be described the
+information of the interruption in the node.
+
+Example:
+
+       battery-charger@36 {
+               compatible = "maxim,max17040";
+               reg = <0x36>;
+               maxim,alert-soc-level = <10>;
+               interrupt-parent = <&gpio>;
+               interrupts = <18 IRQ_TYPE_EDGE_FALLING>;
+       };
-- 
2.13.3

Reply via email to