wait_for_completion_timeout returns unsigned long not int so an appropriate
variable is declared and the assignment and check fixed up.

Signed-off-by: Nicholas Mc Guire <hof...@osadl.org>
---

found by experimental coccinelle script

As the timeout returned is always << INT_MAX there is no side-effect with the
type conversion here, never the less proper types should be used.

Patch was compile tested with: x86_64_defconfig + CONFIG_SPI=y, CONFIG_IIO=y,
CONFIG_AD7793=y (implies CONFIG_AD_SIGMA_DELTA=y)

Patch is against 4.18-rc5 (localversion-next is next-20180720)

 drivers/iio/adc/ad_sigma_delta.c | 5 +++--
 1 file changed, 3 insertions(+), 2 deletions(-)

diff --git a/drivers/iio/adc/ad_sigma_delta.c b/drivers/iio/adc/ad_sigma_delta.c
index cf1b048..fc95107 100644
--- a/drivers/iio/adc/ad_sigma_delta.c
+++ b/drivers/iio/adc/ad_sigma_delta.c
@@ -209,6 +209,7 @@ static int ad_sd_calibrate(struct ad_sigma_delta 
*sigma_delta,
        unsigned int mode, unsigned int channel)
 {
        int ret;
+       unsigned long timeout;
 
        ret = ad_sigma_delta_set_channel(sigma_delta, channel);
        if (ret)
@@ -224,8 +225,8 @@ static int ad_sd_calibrate(struct ad_sigma_delta 
*sigma_delta,
 
        sigma_delta->irq_dis = false;
        enable_irq(sigma_delta->spi->irq);
-       ret = wait_for_completion_timeout(&sigma_delta->completion, 2*HZ);
-       if (ret == 0) {
+       timeout = wait_for_completion_timeout(&sigma_delta->completion, 2 * HZ);
+       if (timeout == 0) {
                sigma_delta->irq_dis = true;
                disable_irq_nosync(sigma_delta->spi->irq);
                ret = -EIO;
-- 
2.1.4

Reply via email to