* Dmitry Osipenko <[email protected]> [180928 23:55]:
> On 9/29/18 2:17 AM, Dmitry Osipenko wrote:
> > On 9/29/18 1:41 AM, Tony Lindgren wrote:
> >> I'm still getting these errors after init:
> > 
> > Thank you very much again, seems I got what's wrong with your case. The 
> > ti-abb-regulator driver sets the "abb->current_info_idx = -EINVAL" on probe 
> > and that value is getting updated only after the first voltage change, 
> > hence _regulator_get_voltage() returns -22.

OK that's starting to make some sense now thanks.

> > Please try this patch:
> 
> I've revised the patch and here is the current final version.

Hey cool this one works now :) I suggest you rework the whole series
with these fixes. I recall the series had a problem with git bisect
too between the patches. It will make life easier for other people
who may need to git bisect these patches.

Thanks,

Tony

Reply via email to