On 15/11/2018 14:32, Linus Walleij wrote: > Demote the DBx500 PRCMU clocksource to quality 100 and > mark it as NONSTOP so it will still be used for > timekeeping across suspend/resume. > > The Nomadik MTU timer which has higher precision will > be used when the system is up and running, thanks to > the recent changes properly utilizing the suspend > clocksources. > > This was discussed back in 2011 when the driver was > written, but the infrastructure was not available > upstream to use this timer properly. Now the > infrastructure is there, so let's finalize the work. > > Cc: Baolin Wang <[email protected]> > Signed-off-by: Linus Walleij <[email protected]> > ---
Both applied, thanks! -- <http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs Follow Linaro: <http://www.facebook.com/pages/Linaro> Facebook | <http://twitter.com/#!/linaroorg> Twitter | <http://www.linaro.org/linaro-blog/> Blog