On Fri, Nov 16, 2018 at 03:31:14PM +0530, Viresh Kumar wrote:
> Each CPU can (and does) participate in cooling down the system but the
> DT only captures a handful of them, normally CPU0, in the cooling maps.
> Things work by chance currently as under normal circumstances its the
> first CPU of each cluster which is used by the operating systems to
> probe the cooling devices. But as soon as this CPU ordering changes and
> any other CPU is used to bring up the cooling device, we will start
> seeing failures.
> 
> Also the DT is rather incomplete when we list only one CPU in the
> cooling maps, as the hardware doesn't have any such limitations.
> 
> Update cooling maps to include all devices affected by individual trip
> points.
> 
> Signed-off-by: Viresh Kumar <[email protected]>

Applied, thanks!
Maxime

-- 
Maxime Ripard, Bootlin
Embedded Linux and Kernel engineering
https://bootlin.com

Attachment: signature.asc
Description: PGP signature

Reply via email to