Hi Eric, Am 13.02.19 um 01:33 schrieb Eric Anholt: > The clock driver may probe after ours and so we need to pass the > -EPROBE_DEFER out. Fix the other error path while we're here. > > Signed-off-by: Eric Anholt <e...@anholt.net> > Fixes: 670c672608a1 ("soc: bcm: bcm2835-pm: Add support for power domains > under a new binding.") > --- > drivers/soc/bcm/bcm2835-power.c | 30 +++++++++++++++++++++++++----- > 1 file changed, 25 insertions(+), 5 deletions(-) > > diff --git a/drivers/soc/bcm/bcm2835-power.c b/drivers/soc/bcm/bcm2835-power.c > index 4a1b99b773c0..11f9469423f7 100644 > --- a/drivers/soc/bcm/bcm2835-power.c > +++ b/drivers/soc/bcm/bcm2835-power.c > @@ -485,7 +485,7 @@ static int bcm2835_power_pd_power_off(struct > generic_pm_domain *domain) > } > } > > -static void > +static int > bcm2835_init_power_domain(struct bcm2835_power *power, > int pd_xlate_index, const char *name) > { > @@ -493,6 +493,12 @@ bcm2835_init_power_domain(struct bcm2835_power *power, > struct bcm2835_power_domain *dom = &power->domains[pd_xlate_index]; > > dom->clk = devm_clk_get(dev->parent, name); > + if (IS_ERR(dom->clk)) { > + int ret = PTR_ERR(dom->clk); > + > + if (ret == -EPROBE_DEFER) > + return ret; is it safe to proceed in the other error cases? Even it would be more consistent with clk_prepare_enable() to print an error here. > + } > >
Thanks Stefan