Hi Stefan,

On Mon, Feb 18, 2019 at 11:08:34AM +0000, Stefan Chulski wrote:
> HW recommendation upon Serdes reconfiguration are the following:
> 
> 1. Disable port(CTRL0_REG - in XLG/GMAC) 
> 2. Put port in reset (both XLG/GMAC)
> 3. For KR - put in reset MPCS (MAC control clock, RX SD clock, TX SD clock), 
> XPSC is RXAUI/XAUI clock domain
> 4. Power down Serdes lane
> 
> Do reconfiguration of Serdes.
> 
> 5. Enable Serdes lane
> 6. Disable MPCS reset for KR
> 7. Disable port reset (both XLG/GMAC)
> 8. Enable port  (both XLG/GMAC)

For clarity, presumably either the XLG or the GMAC should be released
from reset and enabled at any one time depending on the configured mode,
but never both together?

-- 