On platforms that have a modem, sensor 0 monitors the modem.

Signed-off-by: Amit Kucheria <[email protected]>
---
 arch/arm64/boot/dts/qcom/msm8916.dtsi | 14 ++++++++++++++
 1 file changed, 14 insertions(+)

diff --git a/arch/arm64/boot/dts/qcom/msm8916.dtsi 
b/arch/arm64/boot/dts/qcom/msm8916.dtsi
index 0803ca8c02da..c8aa9a0986d2 100644
--- a/arch/arm64/boot/dts/qcom/msm8916.dtsi
+++ b/arch/arm64/boot/dts/qcom/msm8916.dtsi
@@ -278,7 +278,21 @@
                                        type = "critical";
                                };
                        };
+               };
+
+               modem-thermal {
+                       polling-delay-passive = <250>;
+                       polling-delay = <1000>;
+
+                       thermal-sensors = <&tsens 0>;
 
+                       trips {
+                               modem_alert0: trip-point@0 {
+                                       temperature = <85000>;
+                                       hysteresis = <2000>;
+                                       type = "hot";
+                               };
+                       };
                };
 
        };
-- 
2.17.1