On Tue, Mar 26, 2019 at 10:56:39PM -0700, Sowjanya Komatineni wrote:

> Tegra SPI driver default uses SW CS control for transfers and HW CS
> control can be enabled through SPI client device node DT property
> nvidia,enable-hw-based-cs and is used only for single transfers.

Why have a property - if this feature works and is useful why would a
system ever not want to use it?

> +     single_xfer = list_is_singular(&msg->transfers);
>       list_for_each_entry(xfer, &msg->transfers, transfer_list) {
>               u32 cmd1;
>  
>               reinit_completion(&tspi->xfer_completion);
>  
> -             cmd1 = tegra_spi_setup_transfer_one(spi, xfer, is_first_msg);
> +             cmd1 = tegra_spi_setup_transfer_one(spi, xfer, is_first_msg,
> +                                                 single_xfer);

It's not sufficient to check if there's only one transfer, you also need
to make sure that the driver isn't using cs_change to use non-standard
chip select handling.

Attachment: signature.asc
Description: PGP signature