On 30/05/2019 11:20, Quentin Perret wrote:
> The core CPU cooling infrastructure has power-related functions
> that have only one client: IPA. Since there can be no user of those
> functions if IPA is not compiled in, make sure to guard them with
> checks on CONFIG_THERMAL_GOV_POWER_ALLOCATOR to not waste space
> unnecessarily.
> 
> Suggested-by: Daniel Lezcano <[email protected]>
> Signed-off-by: Quentin Perret <[email protected]>

Acked-by: Daniel Lezcano <[email protected]>

Thanks!

  -- Daniel

> ---
>  drivers/thermal/cpu_cooling.c | 214 +++++++++++++++++-----------------
>  1 file changed, 104 insertions(+), 110 deletions(-)
> 
> diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
> index 4c5db59a619b..498f59ab64b2 100644
> --- a/drivers/thermal/cpu_cooling.c
> +++ b/drivers/thermal/cpu_cooling.c
> @@ -46,7 +46,9 @@
>   */
>  struct freq_table {
>       u32 frequency;
> +#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
>       u32 power;
> +#endif
>  };
>  
>  /**
> @@ -96,28 +98,6 @@ static DEFINE_IDA(cpufreq_ida);
>  static DEFINE_MUTEX(cooling_list_lock);
>  static LIST_HEAD(cpufreq_cdev_list);
>  
> -/* Below code defines functions to be used for cpufreq as cooling device */
> -
> -/**
> - * get_level: Find the level for a particular frequency
> - * @cpufreq_cdev: cpufreq_cdev for which the property is required
> - * @freq: Frequency
> - *
> - * Return: level corresponding to the frequency.
> - */
> -static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev,
> -                            unsigned int freq)
> -{
> -     struct freq_table *freq_table = cpufreq_cdev->freq_table;
> -     unsigned long level;
> -
> -     for (level = 1; level <= cpufreq_cdev->max_level; level++)
> -             if (freq > freq_table[level].frequency)
> -                     break;
> -
> -     return level - 1;
> -}
> -
>  /**
>   * cpufreq_thermal_notifier - notifier callback for cpufreq policy change.
>   * @nb:      struct notifier_block * with callback info.
> @@ -171,6 +151,27 @@ static int cpufreq_thermal_notifier(struct 
> notifier_block *nb,
>       return NOTIFY_OK;
>  }
>  
> +#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
> +/**
> + * get_level: Find the level for a particular frequency
> + * @cpufreq_cdev: cpufreq_cdev for which the property is required
> + * @freq: Frequency
> + *
> + * Return: level corresponding to the frequency.
> + */
> +static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev,
> +                            unsigned int freq)
> +{
> +     struct freq_table *freq_table = cpufreq_cdev->freq_table;
> +     unsigned long level;
> +
> +     for (level = 1; level <= cpufreq_cdev->max_level; level++)
> +             if (freq > freq_table[level].frequency)
> +                     break;
> +
> +     return level - 1;
> +}
> +
>  /**
>   * update_freq_table() - Update the freq table with power numbers
>   * @cpufreq_cdev:    the cpufreq cooling device in which to update the table
> @@ -319,80 +320,6 @@ static u32 get_dynamic_power(struct 
> cpufreq_cooling_device *cpufreq_cdev,
>       return (raw_cpu_power * cpufreq_cdev->last_load) / 100;
>  }
>  
> -/* cpufreq cooling device callback functions are defined below */
> -
> -/**
> - * cpufreq_get_max_state - callback function to get the max cooling state.
> - * @cdev: thermal cooling device pointer.
> - * @state: fill this variable with the max cooling state.
> - *
> - * Callback for the thermal cooling device to return the cpufreq
> - * max cooling state.
> - *
> - * Return: 0 on success, an error code otherwise.
> - */
> -static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
> -                              unsigned long *state)
> -{
> -     struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
> -
> -     *state = cpufreq_cdev->max_level;
> -     return 0;
> -}
> -
> -/**
> - * cpufreq_get_cur_state - callback function to get the current cooling 
> state.
> - * @cdev: thermal cooling device pointer.
> - * @state: fill this variable with the current cooling state.
> - *
> - * Callback for the thermal cooling device to return the cpufreq
> - * current cooling state.
> - *
> - * Return: 0 on success, an error code otherwise.
> - */
> -static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
> -                              unsigned long *state)
> -{
> -     struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
> -
> -     *state = cpufreq_cdev->cpufreq_state;
> -
> -     return 0;
> -}
> -
> -/**
> - * cpufreq_set_cur_state - callback function to set the current cooling 
> state.
> - * @cdev: thermal cooling device pointer.
> - * @state: set this variable to the current cooling state.
> - *
> - * Callback for the thermal cooling device to change the cpufreq
> - * current cooling state.
> - *
> - * Return: 0 on success, an error code otherwise.
> - */
> -static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
> -                              unsigned long state)
> -{
> -     struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
> -     unsigned int clip_freq;
> -
> -     /* Request state should be less than max_level */
> -     if (WARN_ON(state > cpufreq_cdev->max_level))
> -             return -EINVAL;
> -
> -     /* Check if the old cooling action is same as new cooling action */
> -     if (cpufreq_cdev->cpufreq_state == state)
> -             return 0;
> -
> -     clip_freq = cpufreq_cdev->freq_table[state].frequency;
> -     cpufreq_cdev->cpufreq_state = state;
> -     cpufreq_cdev->clipped_freq = clip_freq;
> -
> -     cpufreq_update_policy(cpufreq_cdev->policy->cpu);
> -
> -     return 0;
> -}
> -
>  /**
>   * cpufreq_get_requested_power() - get the current power
>   * @cdev:    &thermal_cooling_device pointer
> @@ -536,22 +463,88 @@ static int cpufreq_power2state(struct 
> thermal_cooling_device *cdev,
>                                     power);
>       return 0;
>  }
> +#endif /* CONFIG_THERMAL_GOV_POWER_ALLOCATOR */
> +
> +/* cpufreq cooling device callback functions are defined below */
> +
> +/**
> + * cpufreq_get_max_state - callback function to get the max cooling state.
> + * @cdev: thermal cooling device pointer.
> + * @state: fill this variable with the max cooling state.
> + *
> + * Callback for the thermal cooling device to return the cpufreq
> + * max cooling state.
> + *
> + * Return: 0 on success, an error code otherwise.
> + */
> +static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
> +                              unsigned long *state)
> +{
> +     struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
> +
> +     *state = cpufreq_cdev->max_level;
> +     return 0;
> +}
> +
> +/**
> + * cpufreq_get_cur_state - callback function to get the current cooling 
> state.
> + * @cdev: thermal cooling device pointer.
> + * @state: fill this variable with the current cooling state.
> + *
> + * Callback for the thermal cooling device to return the cpufreq
> + * current cooling state.
> + *
> + * Return: 0 on success, an error code otherwise.
> + */
> +static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
> +                              unsigned long *state)
> +{
> +     struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
> +
> +     *state = cpufreq_cdev->cpufreq_state;
> +
> +     return 0;
> +}
> +
> +/**
> + * cpufreq_set_cur_state - callback function to set the current cooling 
> state.
> + * @cdev: thermal cooling device pointer.
> + * @state: set this variable to the current cooling state.
> + *
> + * Callback for the thermal cooling device to change the cpufreq
> + * current cooling state.
> + *
> + * Return: 0 on success, an error code otherwise.
> + */
> +static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
> +                              unsigned long state)
> +{
> +     struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
> +     unsigned int clip_freq;
> +
> +     /* Request state should be less than max_level */
> +     if (WARN_ON(state > cpufreq_cdev->max_level))
> +             return -EINVAL;
> +
> +     /* Check if the old cooling action is same as new cooling action */
> +     if (cpufreq_cdev->cpufreq_state == state)
> +             return 0;
> +
> +     clip_freq = cpufreq_cdev->freq_table[state].frequency;
> +     cpufreq_cdev->cpufreq_state = state;
> +     cpufreq_cdev->clipped_freq = clip_freq;
> +
> +     cpufreq_update_policy(cpufreq_cdev->policy->cpu);
> +
> +     return 0;
> +}
>  
>  /* Bind cpufreq callbacks to thermal cooling device ops */
>  
>  static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
> -     .get_max_state = cpufreq_get_max_state,
> -     .get_cur_state = cpufreq_get_cur_state,
> -     .set_cur_state = cpufreq_set_cur_state,
> -};
> -
> -static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = {
>       .get_max_state          = cpufreq_get_max_state,
>       .get_cur_state          = cpufreq_get_cur_state,
>       .set_cur_state          = cpufreq_set_cur_state,
> -     .get_requested_power    = cpufreq_get_requested_power,
> -     .state2power            = cpufreq_state2power,
> -     .power2state            = cpufreq_power2state,
>  };
>  
>  /* Notifier for cpufreq policy change */
> @@ -659,18 +652,19 @@ __cpufreq_cooling_register(struct device_node *np,
>                       pr_debug("%s: freq:%u KHz\n", __func__, freq);
>       }
>  
> +     cooling_ops = &cpufreq_cooling_ops;
> +#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
>       if (capacitance) {
>               ret = update_freq_table(cpufreq_cdev, capacitance);
>               if (ret) {
>                       cdev = ERR_PTR(ret);
>                       goto remove_ida;
>               }
> -
> -             cooling_ops = &cpufreq_power_cooling_ops;
> -     } else {
> -             cooling_ops = &cpufreq_cooling_ops;
> +             cooling_ops->get_requested_power = cpufreq_get_requested_power;
> +             cooling_ops->state2power = cpufreq_state2power;
> +             cooling_ops->power2state = cpufreq_power2state;
>       }
> -
> +#endif
>       cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev,
>                                                 cooling_ops);
>       if (IS_ERR(cdev))
> 


-- 
 <http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs

Follow Linaro:  <http://www.facebook.com/pages/Linaro> Facebook |
<http://twitter.com/#!/linaroorg> Twitter |
<http://www.linaro.org/linaro-blog/> Blog

Reply via email to