On Mon, Jun 10, 2019 at 7:13 PM Grygorii Strashko
<[email protected]> wrote:

> From: Russell King <[email protected]>
>
> When a GPIO block has the set/clear dataout registers implemented, it
> also has the normal dataout register implemented. Reading this register
> reads the current GPIO output state, and writing it sets the GPIOs to
> the explicit state. This is the behaviour that we want when saving and
> restoring the context, so use the dataout register exclusively.
>
> Signed-off-by: Russell King <[email protected]>
> Signed-off-by: Grygorii Strashko <[email protected]>

Patch applied.

Yours,
Linus Walleij