From: Magnus Damm <damm+rene...@opensource.se>

Update the CMT driver to mark "renesas,cmt-48" as deprecated.

Instead of documenting a theoretical hardware device based on current software
support level, define DT bindings top-down based on available data sheet
information and make use of part numbers in the DT compat string.

In case of the only in-tree users r8a7740 and sh73a0 the compat strings
"renesas,r8a7740-cmt1" and "renesas,sh73a0-cmt1" may be used instead.

Signed-off-by: Magnus Damm <damm+rene...@opensource.se>
---

 drivers/clocksource/sh_cmt.c |    6 +++++-
 1 file changed, 5 insertions(+), 1 deletion(-)

--- 0011/drivers/clocksource/sh_cmt.c
+++ work/drivers/clocksource/sh_cmt.c   2019-07-18 19:31:01.917491800 +0900
@@ -921,7 +921,11 @@ static const struct platform_device_id s
 MODULE_DEVICE_TABLE(platform, sh_cmt_id_table);
 
 static const struct of_device_id sh_cmt_of_table[] __maybe_unused = {
-       { .compatible = "renesas,cmt-48", .data = &sh_cmt_info[SH_CMT_48BIT] },
+       {
+               /* deprecated, preserved for backward compatibility */
+               .compatible = "renesas,cmt-48",
+               .data = &sh_cmt_info[SH_CMT_48BIT]
+       },
        {
                /* deprecated, preserved for backward compatibility */
                .compatible = "renesas,cmt-48-gen2",

Reply via email to