On 31/07/2019 08:14, Stefan Mavrodiev wrote:
Like in H3, A64 SID controller doesn't return correct data
when using direct access. It appears that on A64, SID needs
8 bytes of word_size.

Workaround is to enable read by registers.

Signed-off-by: Stefan Mavrodiev <ste...@olimex.com>

Applied Thanks,
srini