Quoting Peng Fan (2019-08-27 01:17:50)
> From: Peng Fan <peng....@nxp.com>
> 
> There is hardware issue that:
> The output clock the LPCG cell will not turn back on as expected,
> even though a read of the IPG registers in the LPCG indicates that
> the clock should be enabled.
> 
> The software workaround is to write twice to enable the LPCG clock
> output.
> 
> Signed-off-by: Peng Fan <peng....@nxp.com>

Does this need a Fixes tag?