From: Yuechao Zhao <yuechao.z...@advantech.com.cn>

The timeout module parameter should not be used for setting the default
timeout. Because, if you set the timeout = 0, the default timeout will
be meaningless. And the timeout module parameter of 0 means "no timeout
module paraameter specified".

Signed-off-by: Yuechao Zhao <yuechao.z...@advantech.com.cn>
---
Change in v3:
- replace 'static int timeout = WATCHDOG_TIMEOUT;' with 'static int timeout;'
- fixed typo

Change in v2:
- modify subject to 'hwmon:(nct7904) Set default timeout'
---
 drivers/hwmon/nct7904.c | 8 ++++----
 1 file changed, 4 insertions(+), 4 deletions(-)

diff --git a/drivers/hwmon/nct7904.c b/drivers/hwmon/nct7904.c
index 18c95be..b042569 100644
--- a/drivers/hwmon/nct7904.c
+++ b/drivers/hwmon/nct7904.c
@@ -111,14 +111,14 @@
 #define MIN_TIMEOUT            (1 * 60)
 #define MAX_TIMEOUT            (255 * 60)
 
-static int timeout = WATCHDOG_TIMEOUT;
+static int timeout;
 module_param(timeout, int, 0);
 MODULE_PARM_DESC(timeout, "Watchdog timeout in minutes. 1 <= timeout <= 255, 
default="
-                       __MODULE_STRING(WATCHODOG_TIMEOUT) ".");
+                       __MODULE_STRING(WATCHDOG_TIMEOUT) ".");
 
 static bool nowayout = WATCHDOG_NOWAYOUT;
 module_param(nowayout, bool, 0);
-MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once started once 
started (default="
+MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once started (default="
                        __MODULE_STRING(WATCHDOG_NOWAYOUT) ")");
 
 static const unsigned short normal_i2c[] = {
@@ -1147,7 +1147,7 @@ static int nct7904_probe(struct i2c_client *client,
        data->wdt.ops = &nct7904_wdt_ops;
        data->wdt.info = &nct7904_wdt_info;
 
-       data->wdt.timeout = timeout * 60; /* in seconds */
+       data->wdt.timeout = WATCHDOG_TIMEOUT * 60; /* Set default timeout */
        data->wdt.min_timeout = MIN_TIMEOUT;
        data->wdt.max_timeout = MAX_TIMEOUT;
        data->wdt.parent = &client->dev;
-- 
1.8.3.1