24.07.2020 02:50, Sowjanya Komatineni пишет:
> Tegra VI I2C is part of VE power domain and typically used for
> camera usecases.
> 
> VE power domain is not always on and is non-IRQ safe. So, IRQ safe
> device cannot be attached to a non-IRQ safe domain as it prevents
> powering off the PM domain and generic power domain driver will warn.
> 
> Current driver marks all I2C devices as IRQ safe and VI I2C device
> does not require IRQ safe as it will not be used for atomic transfers.
> 
> This patch has fix to make VI I2C as non-IRQ safe.
> 
> Signed-off-by: Sowjanya Komatineni <skomatin...@nvidia.com>
> ---
>  drivers/i2c/busses/i2c-tegra.c | 10 +++++++++-
>  1 file changed, 9 insertions(+), 1 deletion(-)
> 
> diff --git a/drivers/i2c/busses/i2c-tegra.c b/drivers/i2c/busses/i2c-tegra.c
> index 1577296..3be1018 100644
> --- a/drivers/i2c/busses/i2c-tegra.c
> +++ b/drivers/i2c/busses/i2c-tegra.c
> @@ -1750,7 +1750,15 @@ static int tegra_i2c_probe(struct platform_device 
> *pdev)
>               goto unprepare_slow_clk;
>       }
>  
> -     pm_runtime_irq_safe(&pdev->dev);
> +     /*
> +      * VI I2C is in VE power domain which is not always on and not
> +      * an IRQ safe. So, IRQ safe device can't be attached to a non-IRQ
> +      * safe domain as it prevents powering off the PM domain.
> +      * Also, VI I2C device don't need to use runtime IRQ safe as it will
> +      * not be used for atomic transfers.
> +      */
> +     if (!i2c_dev->is_vi)
> +             pm_runtime_irq_safe(&pdev->dev);
>       pm_runtime_enable(&pdev->dev);
>       if (!pm_runtime_enabled(&pdev->dev)) {
>               ret = tegra_i2c_runtime_resume(&pdev->dev);
> 

Reviewed-by: Dmitry Osipenko <dig...@gmail.com>

Reply via email to