On Fri, Sep 25, 2020 at 03:44:39PM +0300, Ivan Khoronzhuk wrote: > To start also "phy state machine", with UP state as it should be, > the phy_start() has to be used, in another case machine even is not > triggered. After this change negotiation is supposed to be triggered > by SM workqueue. > > It's not correct usage, but it appears after the following patch, > so add it as a fix. > > Fixes: 74a992b3598a ("net: phy: add phy_check_link_status") > Signed-off-by: Ivan Khoronzhuk <ikhor...@cisco.com> > --- > > Based on net/master
Hi Ivan In the future, please make the patch subject [PATCH net] to make it clear which tree it is for. Reviewed-by: Andrew Lunn <and...@lunn.ch> Andrew