On Fri, Sep 25, 2020 at 03:44:39PM +0300, Ivan Khoronzhuk wrote:
> To start also "phy state machine", with UP state as it should be,
> the phy_start() has to be used, in another case machine even is not
> triggered. After this change negotiation is supposed to be triggered
> by SM workqueue.
> 
> It's not correct usage, but it appears after the following patch,
> so add it as a fix.
> 
> Fixes: 74a992b3598a ("net: phy: add phy_check_link_status")
> Signed-off-by: Ivan Khoronzhuk <ikhor...@cisco.com>
> ---
> 
> Based on net/master

Hi Ivan

In the future, please make the patch subject [PATCH net] to make it
clear which tree it is for.

Reviewed-by: Andrew Lunn <and...@lunn.ch>

    Andrew