On Thu, 11 Mar 2021 12:21:41 +0200, Matti Vaittinen wrote:
> Support specifying protection/error/warning limits for regulator
> over current, over temperature and over/under voltage.
> 
> Most of the PMICs support only "protection" feature but few
> setups do also support error/warning level indications.
> 
> On many ICs most of the protection limits can't actually be set.
> But for example the ampere limit for over-current protection on ROHM
> BD9576 can be configured - or feature can be completely disabled.
> 
> Provide limit setting for all protections/errors for the sake of
> the completeness and do that using own properties for all so that
> not all users would need to set all levels when only one or few are
> supported.
> 
> Signed-off-by: Matti Vaittinen <[email protected]>
> ---
> v3:
>  No changes.
> v2:
>  Shortended property names as suggested by Rob.
> 
>  .../bindings/regulator/regulator.yaml         | 82 +++++++++++++++++++
>  1 file changed, 82 insertions(+)
> 

Reviewed-by: Rob Herring <[email protected]>