Convert msm9860 driver to reg_field to use the init_common
function.

Signed-off-by: Ansuel Smith <ansuels...@gmail.com>
Acked-by: Thara Gopinath <thara.gopin...@linaro.org>
---
 drivers/thermal/qcom/tsens-8960.c | 73 ++++++++++++++++++++++++++++++-
 1 file changed, 71 insertions(+), 2 deletions(-)

diff --git a/drivers/thermal/qcom/tsens-8960.c 
b/drivers/thermal/qcom/tsens-8960.c
index 2a28a5af2..0d0c2647d 100644
--- a/drivers/thermal/qcom/tsens-8960.c
+++ b/drivers/thermal/qcom/tsens-8960.c
@@ -51,11 +51,22 @@
 #define MIN_LIMIT_TH           0x0
 #define MAX_LIMIT_TH           0xff
 
-#define S0_STATUS_ADDR         0x3628
 #define INT_STATUS_ADDR                0x363c
 #define TRDY_MASK              BIT(7)
 #define TIMEOUT_US             100
 
+#define S0_STATUS_OFF          0x3628
+#define S1_STATUS_OFF          0x362c
+#define S2_STATUS_OFF          0x3630
+#define S3_STATUS_OFF          0x3634
+#define S4_STATUS_OFF          0x3638
+#define S5_STATUS_OFF          0x3664  /* Sensors 5-10 found on 
apq8064/msm8960 */
+#define S6_STATUS_OFF          0x3668
+#define S7_STATUS_OFF          0x366c
+#define S8_STATUS_OFF          0x3670
+#define S9_STATUS_OFF          0x3674
+#define S10_STATUS_OFF         0x3678
+
 static int suspend_8960(struct tsens_priv *priv)
 {
        int ret;
@@ -179,7 +190,7 @@ static int init_8960(struct tsens_priv *priv)
         */
        for (i = 0; i < priv->num_sensors; i++) {
                if (i >= 5)
-                       priv->sensor[i].status = S0_STATUS_ADDR + 40;
+                       priv->sensor[i].status = S0_STATUS_OFF + 40;
                priv->sensor[i].status += i * 4;
        }
 
@@ -269,6 +280,63 @@ static int get_temp_8960(const struct tsens_sensor *s, int 
*temp)
        return -ETIMEDOUT;
 }
 
+static const struct reg_field tsens_8960_regfields[MAX_REGFIELDS] = {
+       /* ----- SROT ------ */
+       /* No VERSION information */
+
+       /* CNTL */
+       [TSENS_EN]     = REG_FIELD(CNTL_ADDR,  0, 0),
+       [TSENS_SW_RST] = REG_FIELD(CNTL_ADDR,  1, 1),
+       /* 8960 has 5 sensors, 8660 has 11, we only handle 5 */
+       [SENSOR_EN]    = REG_FIELD(CNTL_ADDR,  3, 7),
+
+       /* ----- TM ------ */
+       /* INTERRUPT ENABLE */
+       /* NO INTERRUPT ENABLE */
+
+       /* Single UPPER/LOWER TEMPERATURE THRESHOLD for all sensors */
+       [LOW_THRESH_0]   = REG_FIELD(THRESHOLD_ADDR,  0,  7),
+       [UP_THRESH_0]    = REG_FIELD(THRESHOLD_ADDR,  8, 15),
+       /* MIN_THRESH_0 and MAX_THRESH_0 are not present in the regfield
+        * Recycle CRIT_THRESH_0 and 1 to set the required regs to hardcoded 
temp
+        * MIN_THRESH_0 -> CRIT_THRESH_1
+        * MAX_THRESH_0 -> CRIT_THRESH_0
+        */
+       [CRIT_THRESH_1]   = REG_FIELD(THRESHOLD_ADDR, 16, 23),
+       [CRIT_THRESH_0]   = REG_FIELD(THRESHOLD_ADDR, 24, 31),
+
+       /* UPPER/LOWER INTERRUPT [CLEAR/STATUS] */
+       /* 1 == clear, 0 == normal operation */
+       [LOW_INT_CLEAR_0]   = REG_FIELD(CNTL_ADDR,  9,  9),
+       [UP_INT_CLEAR_0]    = REG_FIELD(CNTL_ADDR, 10, 10),
+
+       /* NO CRITICAL INTERRUPT SUPPORT on 8960 */
+
+       /* Sn_STATUS */
+       [LAST_TEMP_0]  = REG_FIELD(S0_STATUS_OFF,  0,  7),
+       [LAST_TEMP_1]  = REG_FIELD(S1_STATUS_OFF,  0,  7),
+       [LAST_TEMP_2]  = REG_FIELD(S2_STATUS_OFF,  0,  7),
+       [LAST_TEMP_3]  = REG_FIELD(S3_STATUS_OFF,  0,  7),
+       [LAST_TEMP_4]  = REG_FIELD(S4_STATUS_OFF,  0,  7),
+       [LAST_TEMP_5]  = REG_FIELD(S5_STATUS_OFF,  0,  7),
+       [LAST_TEMP_6]  = REG_FIELD(S6_STATUS_OFF,  0,  7),
+       [LAST_TEMP_7]  = REG_FIELD(S7_STATUS_OFF,  0,  7),
+       [LAST_TEMP_8]  = REG_FIELD(S8_STATUS_OFF,  0,  7),
+       [LAST_TEMP_9]  = REG_FIELD(S9_STATUS_OFF,  0,  7),
+       [LAST_TEMP_10] = REG_FIELD(S10_STATUS_OFF, 0,  7),
+
+       /* No VALID field on 8960 */
+       /* TSENS_INT_STATUS bits: 1 == threshold violated */
+       [MIN_STATUS_0] = REG_FIELD(INT_STATUS_ADDR, 0, 0),
+       [LOWER_STATUS_0] = REG_FIELD(INT_STATUS_ADDR, 1, 1),
+       [UPPER_STATUS_0] = REG_FIELD(INT_STATUS_ADDR, 2, 2),
+       /* No CRITICAL field on 8960 */
+       [MAX_STATUS_0] = REG_FIELD(INT_STATUS_ADDR, 3, 3),
+
+       /* TRDY: 1=ready, 0=in progress */
+       [TRDY] = REG_FIELD(INT_STATUS_ADDR, 7, 7),
+};
+
 static const struct tsens_ops ops_8960 = {
        .init           = init_8960,
        .calibrate      = calibrate_8960,
@@ -282,4 +350,5 @@ static const struct tsens_ops ops_8960 = {
 struct tsens_plat_data data_8960 = {
        .num_sensors    = 11,
        .ops            = &ops_8960,
+       .fields         = tsens_8960_regfields,
 };
-- 
2.30.2