The Harmony board has an ON Semiconductors NCT1008 temperature sensor
connected to the DVC bus. It can be used to monitor the ambient (local)
and on-die (remote) temperatures.

Signed-off-by: Thierry Reding <[email protected]>
Tested-by: Stephen Warren <[email protected]>
---
 arch/arm/boot/dts/tegra20-ventana.dts | 5 +++++
 1 file changed, 5 insertions(+)

diff --git a/arch/arm/boot/dts/tegra20-ventana.dts 
b/arch/arm/boot/dts/tegra20-ventana.dts
index 1dde0d3..adc4754 100644
--- a/arch/arm/boot/dts/tegra20-ventana.dts
+++ b/arch/arm/boot/dts/tegra20-ventana.dts
@@ -473,6 +473,11 @@
                                };
                        };
                };
+
+               temperature-sensor@4c {
+                       compatible = "onnn,nct1008";
+                       reg = <0x4c>;
+               };
        };
 
        pmc {
-- 
1.8.0

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/