> -----Original Message-----
> From: Jonghwa Lee [mailto:[email protected]]
> Sent: Saturday, May 18, 2013 5:51 PM
> To: [email protected]
> Cc: [email protected]; Zhang, Rui; Eduardo Valentin; Amit
> Dinel Kachhap; Jonghwa Lee; MyungJoo Ham
> Subject: [PATCH 3/3] Thermal:core: Handle trips focused on current trip
> point only.
> Importance: High
> 
> When thermal zone device is updated, it doesn't need to check every
> trip points and its handling mathod even current temperature doesn't
> exceed the trip's temperature. To modify those dissipatve mechanism,
> this patch introduces the way to get current thermal trip point to call
> only correspond trip point handling.
> 
> Signed-off-by: Jonghwa Lee <[email protected]>
> Signed-off-by: MyungJoo Ham <[email protected]>

NAK.

> ---
>  drivers/thermal/thermal_core.c |   28 +++++++++++++++++-----------
>  1 file changed, 17 insertions(+), 11 deletions(-)
> 
> diff --git a/drivers/thermal/thermal_core.c
> b/drivers/thermal/thermal_core.c index ce4384a..1cc4825 100644
> --- a/drivers/thermal/thermal_core.c
> +++ b/drivers/thermal/thermal_core.c
> @@ -333,14 +333,6 @@ static void handle_non_critical_trips(struct
> thermal_zone_device *tz,  static void handle_critical_trips(struct
> thermal_zone_device *tz,
>                               int trip, enum thermal_trip_type trip_type)  {
> -     long trip_temp;
> -
> -     tz->ops->get_trip_temp(tz, trip, &trip_temp);
> -
> -     /* If we have not crossed the trip_temp, we do not care. */
> -     if (tz->temperature < trip_temp)
> -             return;
> -
>       if (tz->ops->notify)
>               tz->ops->notify(tz, trip, trip_type);
> 
> @@ -437,14 +429,28 @@ static void update_temperature(struct
> thermal_zone_device *tz)
>       mutex_unlock(&tz->lock);
>  }
> 
> +static int thermal_zone_get_current_trip(struct thermal_zone_device
> +*tz) {
> +     int trip;
> +     long trip_temp;
> +
> +     for (trip = tz->trips - 1; trip > 0; trip--) {
> +             tz->ops->get_trip_temp(tz, trip, &trip_temp);
> +             if (tz->temperature > trip_temp)
> +                     continue;
> +     }
> +     return trip;
> +}
> +
>  void thermal_zone_device_update(struct thermal_zone_device *tz)  {
> -     int count;
> +     int trip;
> 
>       update_temperature(tz);
> 
> -     for (count = 0; count < tz->trips; count++)
> -             handle_thermal_trip(tz, count);
> +     trip = thermal_zone_get_current_trip(tz);
> +
> +     handle_thermal_trip(tz, trip);

Say, trip point 1 for thermal zone 0 is 60C,
The system is running above 60C for somethime,
thus the thermal_instance for this trip point is running at upper_limit.
When the temperature suddenly drops below 60C,
we still need to handle trip point 1 to deactivate it.

Thanks,
rui
>  }
>  EXPORT_SYMBOL_GPL(thermal_zone_device_update);
> 
> --
> 1.7.9.5

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to