On Tue, Dec 03, 2013 at 11:18:47PM +0100, Stefan Agner wrote:
> Depending on the regulator version, the voltage table might be
> different. Use version specific regulator tables in order to select
> correct voltage table. For the following regulator versions different
> voltage tables are now used:

Acked-by: Mark Brown <[email protected]>

I won't apply since I think that patch 3 needs to go along with this,
unless people decide the regulator tree is the easiest way to merge.

Attachment: signature.asc