Now that we can distinguish between multiple domains carrying the
same device_node, tag the raw ITS domain with DOMAIN_BUS_NEXUS.
This will allow MSI providers built on top of the raw ITS domain
to identify it.

Signed-off-by: Marc Zyngier <marc.zyng...@arm.com>
---
 drivers/irqchip/irq-gic-v3-its.c | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/drivers/irqchip/irq-gic-v3-its.c b/drivers/irqchip/irq-gic-v3-its.c
index 7c01fe4..760467d 100644
--- a/drivers/irqchip/irq-gic-v3-its.c
+++ b/drivers/irqchip/irq-gic-v3-its.c
@@ -1407,13 +1407,14 @@ static int its_probe(struct device_node *node, struct 
irq_domain *parent)
        writel_relaxed(GITS_CTLR_ENABLE, its->base + GITS_CTLR);
 
        if (of_property_read_bool(its->msi_chip.of_node, "msi-controller")) {
-               its->domain = irq_domain_add_tree(NULL, &its_domain_ops, its);
+               its->domain = irq_domain_add_tree(node, &its_domain_ops, its);
                if (!its->domain) {
                        err = -ENOMEM;
                        goto out_free_tables;
                }
 
                its->domain->parent = parent;
+               its->domain->bus_token = DOMAIN_BUS_NEXUS;
 
                its->msi_chip.domain = its_pci_msi_alloc_domain(node,
                                                                its->domain);
-- 
2.1.4

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to