> From: DEMERRE DIETER <[EMAIL PROTECTED]>
> Date: Mon, 29 Nov 1999 09:47:45 +0100
> to a NIC or a NIC driver. I get *lots* of errors on a certain NIC.
> RX packets:2731402 errors:35669 dropped:0 overruns:30799 frame:35669
> TX packets:2348317 errors:0 dropped:0 overruns:0 carrier:0 collisions:53186
>txqueuelen:100
I am afraid I have bad news for you:
Typical symptoms of some wrong signal getting to the cable.
I have seens exactly the same when mains signal got there.
Possibilities: on coax, the shield has multiple grounding
(I remember a long discussion on some newsgroup how such
a cable should be grounded; multiple grounding causes
mains signal to be present on the cable); on TP, the hub
has damaged port (isolation damaged - try another port on
the hub); or card transceiver damaged; or cable damaged
(isolation broken) and touching not isolated mains cable.
Unless the first possibility, many devices may be damaged -
breaking isolation in one would not produce such a symptoms.
Be careful touching the cables - there may be mains voltage!
Jerzy
-