On Thu, Mar 21, 2019 at 9:06 PM Dexuan Cui <de...@microsoft.com> wrote: > > > From: Dexuan Cui > > Sent: Thursday, March 21, 2019 7:09 PM > > > IMO there are 2 issues in ndctl/monitor.c: filter_dimm(): > > > > 1. IMO the cmd numbers ND_CMD_SMART (1) and > > ND_CMD_SMART_THRESHOLD(2) are not really device-neutral. They > > work for ndctl/lib/intel.c and it looks they happen to work for > > ndctl/lib/hpe1.c, as hpe "happens" to have: > > NDN_HPE1_CMD_SMART = 1, > > NDN_HPE1_CMD_SMART_THRESHOLD = 2, > > > > But for ndctl/lib/msft.c, 1 and 2 mean different things. See [1]. > > So the current "ndctl monitor" can't support msft.c. > > > > For ndctl/lib/hyperv.c, 1 and 2 means: > > ND_HYPERV_CMD_GET_HEALTH_INFO = 1, > > ND_HYPERV_CMD_GET_SHUTDOWN_INFO = 2, > > They're also incompatible with ND_CMD_SMART and > > ND_CMD_SMART_THRESHOLD. > > Of source, the current code can "work" since these ND_HYPERV_CMD* > > numbers happen to be the same as ND_CMD_SMART and > > ND_CMD_SMART_THRESHOLD. So this may not be an isue for hyperv.c. > > Actually, this _is_ an issue for NVDIMM_FAMILY_HYPERV (and the other > families except for NVDIMM_FAMILY_INTEL) : see the kernel function > acpi_nfit_register_dimms(), where ND_CMD_SMART is set in the > "cmd_mask" only for NVDIMM_FAMILY_INTEL. > > So, on Hyper-V, ndctl_dimm_is_cmd_supported(dimm, ND_CMD_SMART) > is always false, and "ndctl monitor" exits with "no smart support".
Can the Hyper-V implementation emulate those commands? That's the expectation, i.e. that the implementation can return they required payloads, but it's fine if the payloads disclaim support for certain fields. _______________________________________________ Linux-nvdimm mailing list Linux-nvdimm@lists.01.org https://lists.01.org/mailman/listinfo/linux-nvdimm