We have several DELL R900 server with PERC 6/E adapter in it.  recently one of 
server continue pop-up messages on /var/log/message for switch status between 
"write back" and "write through".

==============================
Dec  6 08:09:31 host01 Server Administrator: Storage Service EventID: 2189  The 
controller write policy has been changed to Write Back.:  Battery 0 Controller 0
Dec  7 13:20:13 host01 Server Administrator: Storage Service EventID: 2188  The 
controller write policy has been changed to Write Through.:  Battery 0 
Controller 0
Dec  9 01:09:39 host01 Server Administrator: Storage Service EventID: 2188  The 
controller write policy has been changed to Write Through.:  Battery 0 
Controller 0
Dec  9 07:38:29 host01 Server Administrator: Storage Service EventID: 2189  The 
controller write policy has been changed to Write Back.:  Battery 0 Controller 0

================================


I double check PERC 6/E is NOT on battery "learn cycle".  When it change to 
"write though" I also use OPMN check status and NO battery low issue.

I tried to use OPMN change status from "write though" to "write back" but it 
not work.

Anyone know why PERC 6/E status continue change?