Hi,
PIII600-256RAM-2X18Go running in RAID-1 
it makes 200-210Go/day

Something arrived to hda:
----------------
Personalities : [raid1] 
read_ahead 1024 sectors
md0 : active raid1 hdc1[1] hda1[0](F) 2048128 blocks [2/1] [_U]
md1 : active raid1 hdc6[1] hda6[0](F) 15430336 blocks [2/1] [_U]
unused devices: <none>
----------------

Questions:
- how can I see if hda is died or just it is an another error ?
- what should I do ? reboot ? shutdown ? change hd right now ?
wait ? help help ...

Octave

dmesg gives:
----------------
Complete Error }
hda: write_intr: error=0x10 { SectorIdNotFound }, LBAsect=1009255, sector=1009199
hda: write_intr error1: nr_sectors=1, stat=0x51
[...]
hda: read_intr: status=0x59 { DriveReady SeekComplete DataRequest Error }
hda: read_intr: error=0x40 { UncorrectableError }, LBAsect=786599, sector=786536
end_request: I/O error, dev 03:01 (hda), sector 786536
raid1: Disk failure on hda1, disabling device. 
       Operation continuing on 1 devices
raid1: md0: rescheduling block 98317
md: recovery thread got woken up ...
md0: no spare disk to reconstruct array! -- continuing in degraded mode
md1: no spare disk to reconstruct array! -- continuing in degraded mode
md: recovery thread finished ...
dirty sb detected, updating.
md: updating md0 RAID superblock on device
hdc1 [events: 00000015](write) hdc1's sb offset: 2048128
(skipping faulty hda1 )
.
raid1: md0: redirecting sector 98317 to another mirror
eth0: Transmit error, Tx status register 82.
trying to hot-add hda6 to md1 ... 
trying to hot-add hda1 to md0 ... 
trying to hot-add hdc6 to md1 ... 

----------------

raidtab
----------------
raiddev             /dev/md0
raid-level                  1
nr-raid-disks               2
chunk-size                  64k
persistent-superblock       1
#nr-spare-disks     0
    device          /dev/hda1
    raid-disk     0
    device          /dev/hdc1
    raid-disk     1
raiddev             /dev/md1
raid-level                  1
nr-raid-disks               2
chunk-size                  64k
persistent-superblock       1
#nr-spare-disks     0
    device          /dev/hda6
    raid-disk     0
    device          /dev/hdc6
    raid-disk     1
----------------






Amicalement,
oCtAvE 

Connexion terminée par expiration du délai d'attente