On Tue, 7 Sep 1999, Michael E. Kyne wrote:

> How does one go about testing these adapters to determine if they do
> properly terminate the High Lines?

I didn't do the job in my company for this problem, however, a few hints:

   - when converting from 68 to 50, the 68 side should not have the
     lines connected together and grounded, they should be terminated to
     a resistor pack, possibly with a voltage regulator if it's active.
   - _active_ termination usually has resistors (packs) AND a voltage
     regulator IC

One easy way is to open the connector. Another is to check connectivity
with a voltmeter/ohmmeter.

Typical 68/50 converters will work only reliably if the whole bus is 50.


-
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to [EMAIL PROTECTED]

Reply via email to