I'll have a look at this tommorrow morning.


On Thu, 13 Apr 2000 [EMAIL PROTECTED] wrote:

> > Hmmm.  Could you give me the definition of a simple data
> file that will
> > duplicate this?  I assume it happens when you use the
> automatically
> > generated program?
> 
> Yes.  A file that demonstrates the problem is as simple as:
> 
>      A          R TESTDFUR
>      A            FIELDA         1A
> 
> [...]
> 
> > So what options would I select in SDA?  Is there an option
> to specify the
> > field must be completely filled?  Is this for numeric or
> alpha fields, or
> > both?
> 
> I just meant fields where I have to enter something in every
> position, like the file above.  If I use UPDDTA on this
> file, then enter a character in FIELDA, the FER indicator
> turns on.  Then when I press Field Exit, the field gets
> cleared.  It should be left as is.
> 
> -- 
> Carey
> 
> +---
> | This is the LINUX5250 Mailing List!
> | To submit a new message, send your mail to [EMAIL PROTECTED]
> | To subscribe to this list send email to [EMAIL PROTECTED]
> | To unsubscribe from this list send email to [EMAIL PROTECTED]
> | Questions should be directed to the list owner/operator: [EMAIL PROTECTED]
> +---
> 

+---
| This is the LINUX5250 Mailing List!
| To submit a new message, send your mail to [EMAIL PROTECTED]
| To subscribe to this list send email to [EMAIL PROTECTED]
| To unsubscribe from this list send email to [EMAIL PROTECTED]
| Questions should be directed to the list owner/operator: [EMAIL PROTECTED]
+---

Reply via email to