In article <[EMAIL PROTECTED]>,
        [EMAIL PROTECTED] (Kiss Gabor) writes:
> ----------------------------------------------------------------------------
> # smartctl -d ata -F samsung -a /dev/sda
> smartctl version 5.36 [x86_64-unknown-linux-gnu] Copyright (C) 2002-6 Bruce 
> Allen
> Home page is http://smartmontools.sourceforge.net/
> 
> === START OF INFORMATION SECTION ===
> Device Model:     SAMSUNG HD160JJ
> Serial Number:    S08HJ1OL808654
> Firmware Version: ZM100-41
> User Capacity:    160,041,885,696 bytes
> Device is:        In smartctl database [for details use: -P show]
> ATA Version is:   7
> ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 4a
> Local Time is:    Tue Jun 12 09:44:59 2007 CEST
> 
> ==> WARNING: May need -F samsung or -F samsung2 enabled; see manual for 
> details.
> 
> SMART support is: Available - device has SMART capability.
> SMART support is: Enabled
> 
> === START OF READ SMART DATA SECTION ===
> SMART overall-health self-assessment test result: PASSED
> 
> General SMART Values:
> Offline data collection status:  (0x02)       Offline data collection activity
>                                       was completed without error.
>                                       Auto Offline Data Collection: Disabled.
> Self-test execution status:      (   0)       The previous self-test routine 
> completed
>                                       without error or no self-test has ever 
>                                       been run.
> Total time to complete Offline 
> data collection:               (3701) seconds.
> Offline data collection
> capabilities:                          (0x5b) SMART execute Offline immediate.
>                                       Auto Offline data collection on/off 
> support.
>                                       Suspend Offline collection upon new
>                                       command.
>                                       Offline surface scan supported.
>                                       Self-test supported.
>                                       No Conveyance Self-test supported.
>                                       Selective Self-test supported.
> SMART capabilities:            (0x0003)       Saves SMART data before entering
>                                       power-saving mode.
>                                       Supports SMART auto save timer.
> Error logging capability:        (0x01)       Error logging supported.
>                                       General Purpose Logging supported.
> Short self-test routine 
> recommended polling time:      (   1) minutes.
> Extended self-test routine
> recommended polling time:      (  61) minutes.
> 
> SMART Attributes Data Structure revision number: 16
> Vendor Specific SMART Attributes with Thresholds:
> ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
> WHEN_FAILED RAW_VALUE
>   1 Raw_Read_Error_Rate     0x000f   253   100   051    Pre-fail  Always      
>  -       0
>   3 Spin_Up_Time            0x0007   100   100   025    Pre-fail  Always      
>  -       5632
>   4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always      
>  -       886
>   5 Reallocated_Sector_Ct   0x0033   253   253   010    Pre-fail  Always      
>  -       0
>   7 Seek_Error_Rate         0x000f   253   253   051    Pre-fail  Always      
>  -       0
>   8 Seek_Time_Performance   0x0025   253   253   015    Pre-fail  Offline     
>  -       0
>   9 Power_On_Hours          0x0032   100   100   000    Old_age   Always      
>  -       1301
>  10 Spin_Retry_Count        0x0033   253   253   051    Pre-fail  Always      
>  -       0
>  11 Calibration_Retry_Count 0x0012   253   253   000    Old_age   Always      
>  -       0
>  12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always      
>  -       469
> 187 Unknown_Attribute       0x0032   001   001   000    Old_age   Always      
>  -       131282
> 190 Unknown_Attribute       0x0022   124   058   000    Old_age   Always      
>  -       38
> 194 Temperature_Celsius     0x0022   124   058   000    Old_age   Always      
>  -       38
> 195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always      
>  -       57898
> 196 Reallocated_Event_Count 0x0032   253   253   000    Old_age   Always      
>  -       0
> 197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always      
>  -       1
> 198 Offline_Uncorrectable   0x0030   253   253   000    Old_age   Offline     
>  -       0
> 199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always      
>  -       0
> 200 Multi_Zone_Error_Rate   0x000a   253   100   000    Old_age   Always      
>  -       0
> 201 Soft_Read_Error_Rate    0x000a   253   100   000    Old_age   Always      
>  -       0
> 202 TA_Increase_Count       0x0032   253   253   000    Old_age   Always      
>  -       0

Az offline teszt utan:


=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 121) The previous self-test completed having
                                        the read element of the test failed.
Total time to complete Offline 
data collection:                 (3701) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  61) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   100   100   051    Pre-fail  Always       
-       0
  3 Spin_Up_Time            0x0007   100   100   025    Pre-fail  Always       
-       5632
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       
-       886
  5 Reallocated_Sector_Ct   0x0033   253   253   010    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   253   253   051    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0025   253   253   015    Pre-fail  Offline      
-       11984
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       1304
 10 Spin_Retry_Count        0x0033   253   253   051    Pre-fail  Always       
-       0
 11 Calibration_Retry_Count 0x0012   253   253   000    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       469
187 Unknown_Attribute       0x0032   001   001   000    Old_age   Always       
-       131282
190 Unknown_Attribute       0x0022   076   058   000    Old_age   Always       
-       54
194 Temperature_Celsius     0x0022   076   058   000    Old_age   Always       
-       54
195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       
-       19582591
196 Reallocated_Event_Count 0x0032   253   253   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       1
198 Offline_Uncorrectable   0x0030   253   253   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x000a   253   100   000    Old_age   Always       
-       0
201 Soft_Read_Error_Rate    0x000a   100   100   000    Old_age   Always       
-       0
202 TA_Increase_Count       0x0032   253   253   000    Old_age   Always       
-       0


-Self-test execution status:      (   0)        The previous self-test routine 
completed
-                                       without error or no self-test has ever 
-                                       been run.
+Self-test execution status:      ( 121)        The previous self-test 
completed having
+                                       the read element of the test failed.

 ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE

-  1 Raw_Read_Error_Rate     0x000f   253   100   051    Pre-fail  Always       
-       0
+  1 Raw_Read_Error_Rate     0x000f   100   100   051    Pre-fail  Always       
-       0

-  8 Seek_Time_Performance   0x0025   253   253   015    Pre-fail  Offline      
-       0
-  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       1301
+  8 Seek_Time_Performance   0x0025   253   253   015    Pre-fail  Offline      
-       11984
+  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       1304

-190 Unknown_Attribute       0x0022   124   058   000    Old_age   Always       
-       38
-194 Temperature_Celsius     0x0022   124   058   000    Old_age   Always       
-       38
-195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       
-       57898
+190 Unknown_Attribute       0x0022   076   058   000    Old_age   Always       
-       54
+194 Temperature_Celsius     0x0022   076   058   000    Old_age   Always       
-       54
+195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       
-       19582591

-201 Soft_Read_Error_Rate    0x000a   253   100   000    Old_age   Always       
-       0
+201 Soft_Read_Error_Rate    0x000a   100   100   000    Old_age   Always       
-       0

Segit ez valamit?
Ja es ez is:

+Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
+# 1  Extended offline    Completed: read failure       90%      1302         
20289144
+# 2  Short offline       Completed: read failure       90%      1301         
20289144


kissg
_________________________________________________
linux lista      -      linux@mlf.linux.rulez.org
http://mlf2.linux.rulez.org/mailman/listinfo/linux

válasz