In article <[EMAIL PROTECTED]>,
        Andras HORVATH <[EMAIL PROTECTED]> writes:
> diszket. Ugy latszik, kifutott a hardver a reallokalhato szektorokbol,
> akkor pedig a kovetkezo legkisebb problema is adatvesztessel fog jarni.

Ha a Reallocated_Sector_Ct mutatja, akkor nem.

Egyebkent eleg kriptikus, amit latok.
Az "Error: UNC 8 sectors at LBA = 0x01359675 = 20289141" nagyjabol
egybevag azzal, amit kiserletezessel deritettem ki, csak en a
20289144..20289151 tartomanyt hoztam ki hibasnak.

Hozzaerto szem mit vel felfedezni az alabbiakban?

kissg

----------------------------------------------------------------------------
# smartctl -d ata -F samsung -a /dev/sda
smartctl version 5.36 [x86_64-unknown-linux-gnu] Copyright (C) 2002-6 Bruce 
Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     SAMSUNG HD160JJ
Serial Number:    S08HJ1OL808654
Firmware Version: ZM100-41
User Capacity:    160,041,885,696 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 4a
Local Time is:    Tue Jun 12 09:44:59 2007 CEST

==> WARNING: May need -F samsung or -F samsung2 enabled; see manual for details.

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (3701) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  61) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   253   100   051    Pre-fail  Always       
-       0
  3 Spin_Up_Time            0x0007   100   100   025    Pre-fail  Always       
-       5632
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       
-       886
  5 Reallocated_Sector_Ct   0x0033   253   253   010    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   253   253   051    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0025   253   253   015    Pre-fail  Offline      
-       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       1301
 10 Spin_Retry_Count        0x0033   253   253   051    Pre-fail  Always       
-       0
 11 Calibration_Retry_Count 0x0012   253   253   000    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       469
187 Unknown_Attribute       0x0032   001   001   000    Old_age   Always       
-       131282
190 Unknown_Attribute       0x0022   124   058   000    Old_age   Always       
-       38
194 Temperature_Celsius     0x0022   124   058   000    Old_age   Always       
-       38
195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       
-       57898
196 Reallocated_Event_Count 0x0032   253   253   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       1
198 Offline_Uncorrectable   0x0030   253   253   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x000a   253   100   000    Old_age   Always       
-       0
201 Soft_Read_Error_Rate    0x000a   253   100   000    Old_age   Always       
-       0
202 TA_Increase_Count       0x0032   253   253   000    Old_age   Always       
-       0

SMART Error Log Version: 1
ATA Error Count: 53760 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 53760 occurred at disk power-on lifetime: 3589 hours (149 days + 13 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 75 96 35 e1  Error: UNC 8 sectors at LBA = 0x01359675 = 20289141

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 08 75 96 35 e1 00  14d+15:00:23.425  READ DMA
  ec 00 46 00 00 00 a0 00  35d+00:12:52.353  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00  35d+00:12:52.353  SET FEATURES [Set transfer mode]
  ec 00 06 78 96 35 a0 00  35d+00:12:52.353  IDENTIFY DEVICE

Error 53759 occurred at disk power-on lifetime: 3589 hours (149 days + 13 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 75 96 35 e1  Error: UNC 8 sectors at LBA = 0x01359675 = 20289141

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 08 75 96 35 e1 00  10d+17:40:20.353  READ DMA
  ec 00 46 00 00 00 a0 00  30d+22:13:12.065  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00  30d+22:13:12.065  SET FEATURES [Set transfer mode]
  ec 00 06 78 96 35 a0 00  30d+22:13:12.065  IDENTIFY DEVICE

Error 53758 occurred at disk power-on lifetime: 3589 hours (149 days + 13 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 75 96 35 e1  Error: UNC 8 sectors at LBA = 0x01359675 = 20289141

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 08 75 96 35 e1 00   6d+15:40:40.065  READ DMA
  ec 00 46 00 00 00 a0 00  27d+00:53:08.993  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00  27d+00:53:08.993  SET FEATURES [Set transfer mode]
  ec 00 06 78 96 35 a0 00  27d+00:53:08.993  IDENTIFY DEVICE

Error 53757 occurred at disk power-on lifetime: 3589 hours (149 days + 13 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 75 96 35 e1  Error: UNC 8 sectors at LBA = 0x01359675 = 20289141

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 08 75 96 35 e1 00   2d+18:20:36.993  READ DMA
  ec 00 46 00 00 00 a0 00  22d+22:53:28.705  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00  22d+22:53:28.705  SET FEATURES [Set transfer mode]
  ec 00 06 78 96 35 a0 00  22d+22:53:28.705  IDENTIFY DEVICE

Error 53756 occurred at disk power-on lifetime: 3589 hours (149 days + 13 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 75 96 35 e1  Error: UNC 8 sectors at LBA = 0x01359675 = 20289141

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 08 75 96 35 e1 00  10d+21:57:01.313  READ DMA
  ec 00 46 00 00 00 a0 00  19d+01:33:25.633  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00  19d+01:33:25.633  SET FEATURES [Set transfer mode]
  ec 00 06 78 96 35 a0 00  44d+12:02:35.393  IDENTIFY DEVICE

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective Self-Test Log Data Structure Revision Number (0) should be 1
SMART Selective self-test log data structure revision number 0
Warning: ATA Specification requires selective self-test log data structure 
revision number = 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

----------------------------------------------------------------------------
_________________________________________________
linux lista      -      linux@mlf.linux.rulez.org
http://mlf2.linux.rulez.org/mailman/listinfo/linux

válasz