Update FMan binding documentation with the newly added workaround for erratum A-009885.
Signed-off-by: Tobias Waldekranz <tob...@waldekranz.com> --- Documentation/devicetree/bindings/net/fsl-fman.txt | 9 +++++++++ 1 file changed, 9 insertions(+) diff --git a/Documentation/devicetree/bindings/net/fsl-fman.txt b/Documentation/devicetree/bindings/net/fsl-fman.txt index c00fb0d22c7b..020337f3c05f 100644 --- a/Documentation/devicetree/bindings/net/fsl-fman.txt +++ b/Documentation/devicetree/bindings/net/fsl-fman.txt @@ -410,6 +410,15 @@ PROPERTIES The settings and programming routines for internal/external MDIO are different. Must be included for internal MDIO. +- fsl,erratum-a009885 + Usage: optional + Value type: <boolean> + Definition: Indicates the presence of the A009885 + erratum describing that the contents of MDIO_DATA may + become corrupt unless it is read within 16 MDC cycles + of MDIO_CFG[BSY] being cleared, when performing an + MDIO read operation. + - fsl,erratum-a011043 Usage: optional Value type: <boolean> -- 2.25.1