On Fri, 03 Apr 2026 05:47:13 +0200, Cássio Gabriel wrote: > > onyx_prepare() accepts 32/44.1/48 kHz PCM playback, but it leaves the > Onyx IEC958 sample-rate status bits at the driver's initial 44.1 kHz > setting in DIG_INFO3. As a result, 32 kHz and 48 kHz PCM streams > advertise a stale IEC958 sample rate unless userspace rewrites IEC958 > Playback Default first. > > Update only the consumer sample-frequency bits in DIG_INFO3 from the PCM > runtime during prepare, resolving the long-standing FIXME in the PCM > playback path while leaving the other user-controlled IEC958 status bits > unchanged. > > Mark IEC958 Playback Default as volatile as well, since prepare() now > changes the exposed register contents outside the control put callback. > > Signed-off-by: Cássio Gabriel <[email protected]>
Applied now to for-next branch. Thanks. Takashi