Use orderly_reboot so userspace will to shut itself down via the reboot
path. This is required for graceful reboot initiated by the BMC, such
as when a user uses ipmitool to issue a 'chassis power cycle' command.

Signed-off-by: Joel Stanley <j...@jms.id.au>
---
 arch/powerpc/platforms/powernv/opal-power.c | 5 +++--
 1 file changed, 3 insertions(+), 2 deletions(-)

diff --git a/arch/powerpc/platforms/powernv/opal-power.c 
b/arch/powerpc/platforms/powernv/opal-power.c
index 48bf5b0..ac46c2c 100644
--- a/arch/powerpc/platforms/powernv/opal-power.c
+++ b/arch/powerpc/platforms/powernv/opal-power.c
@@ -29,8 +29,9 @@ static int opal_power_control_event(struct notifier_block *nb,
 
        switch (type) {
        case SOFT_REBOOT:
-               /* Fall through. The service processor is responsible for
-                * bringing the machine back up */
+               pr_info("OPAL: reboot requested\n");
+               orderly_reboot();
+               break;
        case SOFT_OFF:
                pr_info("OPAL: poweroff requested\n");
                orderly_poweroff(true);
-- 
2.1.4