On Thu, 2015-02-26 at 08:29 +0100, Richard Cochran wrote: > @Jason: Got private email this week from another person using the > I217-LM. Here is what they wrote: > > The offset all of a sudden jumps be 40000+ seconds. I would think > that if it was an issue with just reading the timer that the servo > would help throw out spurious values like that, so I suspect we are > somehow actually corrupting the timer. We wrote our own little test > program that only calls get time on the PTP timer, and when we call > it more frequently than 1us is when we really start corrupting the > timer with a vengeance. > > So that gives a clear cut test case that triggers the bug. > > Thanks, > Richard
Thanks Richard! I will pass this on. Regards, Jake ------------------------------------------------------------------------------ Dive into the World of Parallel Programming The Go Parallel Website, sponsored by Intel and developed in partnership with Slashdot Media, is your hub for all things parallel software development, from weekly thought leadership blogs to news, videos, case studies, tutorials and more. Take a look and join the conversation now. http://goparallel.sourceforge.net/ _______________________________________________ Linuxptp-devel mailing list Linuxptp-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/linuxptp-devel