On Mon, Sep 30, 2019 at 07:16:31PM +0000, Rodney Cummings wrote: > In 1588-2008, 8.2.5.4.3, portDS.logSyncInterval is specified per-port. > If the Sync interval was mandated to be the same on all ports, it would > exist in defaultDS or similar. In 1588-2008, 7.7.2.3, NOTE 1 even provides > an example of why the intervals might differ per-port.
Thanks for that explanation. The linuxptp code has logSyncInterval as a per-port configuration option, so support of this point is given. I just never actually set it per-port. > I only meant that since linuxptp strives to align with the IEEE standards > (for good reason), > it might be better to avoid explicit properties for those documents (e.g. > boolean property > like "AvnuAutomotiveSpec" or "AutosarTimeSyncSpec"). Instead, linuxptp can > provide an > individual property for each non-conformant feature in those documents (e.g. > boolean property > for "transmitAnnounce", default TRUE). +1 Thanks, Richard _______________________________________________ Linuxptp-devel mailing list Linuxptp-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/linuxptp-devel