On Tue, Mar 07, 2017 at 07:57:46AM +0000, Joerg Christian (LWE) wrote:
> When I stepped the master clock I had this result on the slave, no matter 
> what value I use for
> fault_reset_interval. I have always the s0 for 16 seconds.

It's not related to the fault reset interval. In the s0 state the PI
servo is measuring frequency of the clock and the length of the
interval is inversely proportional to the I constant. If you need to
reduce the interval, you can use a larger I constant, or use a
different servo.

-- 
Miroslav Lichvar

------------------------------------------------------------------------------