On Wed, Jul 07, 2021 at 03:02:39PM +0300, Дмитрий Кандыбка wrote:
> I've met with ptp4l timesync issue. Master send SYNC packets without
> timestamp and slave doesn't handle this case when twoStepFlag set to 1. The
> IEEE 1588 standard says that SYNC messages in 2-step ptp don't need
> timestamp. It enough to have timestamp in FOLLOW_UP messages.

No, you are mistaken.  The Sync message needs an ingress time stamp at
the client.

> *Software versions*:
> *# ethtool -i enp2s0f0
>                      *
>     driver: i40e

This one again!   Always causing trouble.

> *linux kernel version: *4.15.0-142-generic

Might be too old.  I guess the i40e driver has bugs.  Try an up to
date kernel.

Good luck,
Richard