Am Dienstag, 18. Februar 2014, 16:27:53 schrieb Vesa:
> On 02/18/2014 02:20 PM, Johannes Lorenz wrote:
> >> The default values of plugins should, however, not be affected of
> >> changing our scale types. We also can not improve the default values, as
> >> they are given by the plugins, and we don't have code to fix every
> >> single plugin.
> 
> LADSPA plugins already have a port descriptor enumerator for informing
> the host when a control should be logarithmic. If we implement the
> functionality, then we can follow that hint and make those ports log scale.

Yes, this is what I've programmed so far. Maybe for some non-LADSPA plugins or 
even sound generators we'd need to apply the scale type "by hand". There will 
probably be a history of bug reports like

  "Hey, in plugin xyz, knob abc is missing a plugin...".

However, these are just improvements, it will work as before if the scale type 
is wrong.

------------------------------------------------------------------------------