Hello Doctors:

I am running a unit commitment simulation for the 24 bus reliability test
system, for a time horizon of 24 hours with an hourly time step.

Problem 1: The wind power input from time series data is not following the
specified pattern.  To fix this, I've tried following the "most_ex6_uc"
example in MOST. I've added the wind data as in the example
"ex_wind_profile_uc". I am certain that in the "wind.xgd_table.data" file
the wind power input is marked with the number 2 for  a "CommitKey" value.
I've removed the wind input from  the mpc data, specifically on "mpc.gen",
"mpc.gencost" and "mpc.reserves", since only using "add_wind" and
"get_profiles" is enough; according to the example.

Nevertheless, I realise that the wind power input is moving freely through
each one of the time steps, whereas in the  "most_ex6_uc" example this is
not the case. I would like my case to follow the hourly wind pattern during
24hrs just like in the example.

I will be very helpful if you could explain to me why this is happening and
how to solve it.

Problem 2: Is it possible to use the final output data of UC? Save it and
use it next with different constraints added to a second  UC problem? I am
interested in saving the data of certain power output of some units after
the simulation is performed. I would like to know how would you approach
this.

As always, thank you very much in advance, your input has been widely
helpful,

best wishes,

-- 
Carlos Ferrandon

Reply via email to