The antivirus already finished the scanning and ready to receive DATA,
> but not fast enough to response the DATA transmitted by sender that's
> trigger winsock error 10054.
> If sender follow Internet Mail Regulation, it should wait till MDaemon
> (receiver) issue 354 Enter mail, end with <CRLF>.<CRLF> before transmit
> the DATA.
> 
> Because the DATA transmission failed, sender (client) have
> responsibilities retry to send till success or failure in between 2-5
> days.
> 
> http://msdn.microsoft.com/en-us/library/aa924071.aspx
> 
> 10054 WSAECONNRESET
> Connection reset by peer. An existing connection was forcibly closed by
> the remote host. This normally results if the peer application on the
> remote host is suddenly stopped, the host is rebooted, or the remote
> host uses a hard close (see setsockopt (Windows Sockets) for more
> information on the SO_LINGER option on the remote socket.) This error
> may also result if a connection was broken due to keep-alive activity
> detecting a failure while one or more operations are in progress.
> Operations that were in progress fail with WSAENETRESET. Subsequent
> operations fail with WSAECONNRESET.
> 
Pak apakah ini bisa ada kesalahan dari sisi kita?

Regards
Benny


-- 
--[MDaemon-L]------------------------------------------------
Milis ini untuk Diskusi antar pengguna MDaemon Mail Server.

Netiket: http://www.netmeister.org/news/learn2quote
Arsip: http://mdaemon-l.dutaint.com
Dokumentasi : http://mdaemon.dutaint.co.id
Henti Langgan: Kirim mail ke MDaemon-L-unsubscribe [at] dutaint.com
Berlangganan: kirim mail ke MDaemon-L-subscribe [at] dutaint.com
Versi terakhir MD 14.5.1, SP 4.5, BES 2.0.2, OC 3.0, SG 3.0.2

Kirim email ke