That's for the 33 point spline DV's (as found on the Bosch "M" series pumps), 
right? (And those values are Nm?)

I thought that (most) of the 61x's used a "MW" series pump, with the hexagonal 
DV, which is 50Nm in one step.

--
John W Reames
jream...@verizon.net
Home: +14106646986
Mobile: +14437915905

On Oct 14, 2013, at 10:50, Peter Frederick <psf...@earthlink.net> wrote:

> They are all the same -- the procedure is to seal the copper washers properly.
> 
> Peter
> 
> _______________________________________
> http://www.okiebenz.com
> 
> To search list archives http://www.okiebenz.com/archive/
> 
> To Unsubscribe or change delivery options go to:
> http://mail.okiebenz.com/mailman/listinfo/mercedes_okiebenz.com