If Mr. Jim's advice of whacking it doesn't work...I'l start proper troubleshooting.
Thanks

Bob Rentfro

----- Original Message ----- From: "Craig McCluskey" <[EMAIL PROTECTED]>
To: "Mercedes Discussion List" <[email protected]>
Sent: Saturday, June 17, 2006 1:08 PM
Subject: Re: [MBZ] O.T. Blower Motor Relays


On Sat, 17 Jun 2006 13:02:10 -0700 "Bob Rentfro" <[EMAIL PROTECTED]> wrote:


>
> Got a voltmeter?
>
> Is there a schematic in the shop manual?

Yup....
Yup....

Turn on the power to the blower and measure between the chassis and the
various parts of the circuit that should have +12 V to see where it gets
lost.

You should look for the answers to questions like the following:

- Is there  power to the blower switch?

- Does the power make it through the blower switch?

- Does the power make it to the blower assembly?

- Does the power make it through the relays as appropriate?


Sort of like tracing a vacuum leak with a MityVac but with electrons
instead.