Donald Snook wrote:
The air is not really getting warmer and I can still hear the blower
motor running, but I am not getting good flow from the center vents.
The symptom has not repeated itself in over a week. Perhaps it was just
too hot and I was pushing it too hard.
Sounds like vacuum leak (probably an actuator has cracked) and without
high vacuum to overcome the leak, the system defaults to defrost.
The things I described would shut off the compressor - not change the
air distribution.
Marshall
--
Marshall Booth (who doesn't respond to unsigned questions)
"der Dieseling Doktor" [EMAIL PROTECTED]
'87 300TD 182Kmi, '85 190D 2.0 161Kmi, '87 190D 2.5 turbo 237kmi, '84
190D 2.2 229Kmi (retired)