> P4 1.8A, retail box HSF, 50C > P4 2.53B, Zalman CuAl HSF, <2000 rpm, 44C > P4 2.66B, Zalman CuAl HSF, <2000 rpm, 45C
and to add a data point... P4 2.53B, Intel retail HSF, 46C (115F) this in an Antec plus1080 case, with 2 case fans running at a very slow speed, the 2 motherboard temp sensors are reading 38C (100F). If I hook the case fans up to straight 12V rather than the speed reduced fan power coming out of the Antec power supply, the case temp drops 5C or more in a matter of seconds, and the CPU temp tracks. hey, speaking of... anyone care to point me to something I can understand on how to configure lm_sensors in Linux to work with an Intel server board? I'm getting no readings... # sensors Can't access /proc file /proc/sys/dev/sensors/chips or /proc/bus/i2c unreadable; Make sure you have done 'modprobe i2c-proc'! # modprobe i2c-proc # sensors No sensors found! (this is with Redhat 8 on a E7501 based dual xeon server board, the SE7501WV2, kernel linux-2.4.18-27.8.0) _________________________________________________________________________ Unsubscribe & list info -- http://www.ndatech.com/mersenne/signup.htm Mersenne Prime FAQ -- http://www.tasam.com/~lrwiman/FAQ-mers