On 11/24/2014 03:30 PM, Matt Larsen - Lists wrote:
We have been doing some firmware upgrades on Mikrotiks from 5.26 to
6.22, and alarms start going off on a few of our locations.   If we have
an AP that has no associations on it, you cannot ping the ip address of
the wireless card after upgrading to 6.22.

Is there a workaround for this?   I have a few places where the alarms
are driving me crazy.

Create a bridge, add the wireless card to the bridge, put IP space on the bridge. I, also, put an administrative MAC on the bridge interface. By doing it this way, you could change the wlan card and no arp issues for customers, plus, the interface is always running, so IP space is always shared via ospf (it is likely this is the issue you are seeing anyway).


--
Butch Evans
702-537-0979
Network Support and Engineering
http://store.wispgear.net/
http://www.butchevans.com/
_______________________________________________
Mikrotik mailing list
Mikrotik@mail.butchevans.com
http://mail.butchevans.com/mailman/listinfo/mikrotik

Visit http://blog.butchevans.com/ for tutorials related to Mikrotik RouterOS

Reply via email to