Yes, that makes sense. Thanks Ian Alan Sussex -----Original Message----- From: ian [mailto:[email protected]] Sent: 02 August 2012 17:26 To: mogtalk2 Subject: Re: [mogtalk2] Indicators not working!
On 01/08/12 19:41, Home wrote: > Just checked and it is the 20amp fuse from the firewall fusebox. > > As you say, it's odd that a 20amp blows before the 15amp. > > Steve > Not so strange. It depends what else the 20A fuse is supplying. Assume for argument's sake that there is another load of say 10A fed by the 20A fuse. That would leave just 10A capacity on the 20A fuse, so in the event of a short or overload, the 20A fuse would blow before the 15A. If that makes any sense... Ian ------------------------------------------- View posts on The Mail Archive http://www.mail-archive.com/[email protected]/ [http://www.mail-archive.com/[email protected]/] Modify Your Subscription: https://www.listbox.com/member/?& Powered by Listbox: http://www.listbox.com ------------------------------------------- View posts on The Mail Archive http://www.mail-archive.com/[email protected]/ [http://www.mail-archive.com/[email protected]/] Modify Your Subscription: https://www.listbox.com/member/?member_id=22459785&id_secret=22459785-4a39ddf8 Powered by Listbox: http://www.listbox.com
