-------- Original Message --------
Subject:        Re: Problem with Landmark software (IDAV)
Date:   Mon, 26 Mar 2012 17:59:19 -0400
From:   Emma Sherratt <[email protected]>
To:     [email protected]



Aurélien,

I have worked a lot with IDAV Landmark, and yes i'm afraid it does
crash. I ended up isolating the few bugs it had and just boycotting that
sequence of events. One thing I found is that you shouldn't add any more
meshes into the project once you've started landmarking (or if you do,
close the software and start it up again). Not sure what you are doing
exactly with the averages- if you want species average of a
configuration of landmarks, i'd suggest you get that once you've done a
Procrustes fit. Landmark -> MorphoJ is a well tested transition, and the
latter take .dta files directly (as NTS fie format).

I'm not sure Landmark is being developed any more, but the original
software author David Wiley has a new piece of software, Checkpoint
(http://www.stratovan.com/products/detail.php?appID=2). It does all that
landmark did plus more. Maybe it'll work better for you?

Best of luck,

Emma

****                       __
     (\   .-.   .-.   /_")
      \\_//^\\_//^\\_//
       `"`   `"`   `"`****

Emma Sherratt, PhD.
Post-Doctoral Fellow in Organismic and Evolutionary Biology
and Museum of Comparative Zoology
Harvard University
26 Oxford St.
Cambridge, MA 02138
[email protected] <mailto:[email protected]>

http://sites.google.com/site/esherratt/




On 26 March 2012 17:50, morphmet <[email protected]
<mailto:[email protected]>> wrote:



    -------- Original Message --------
    Subject:        Problem with Landmark software (IDAV)
    Date:   Sat, 24 Mar 2012 15:31:27 -0400
    From:   Aurélien Mounier <[email protected]
    <mailto:[email protected]>>
    To: [email protected] <mailto:[email protected]>



    Dear colleagues,

    I am currently using the Landmark software (IDAV) to work on 3D surface
    scans of craniums.
    I've been facing some problems with the software: it crashes a lot
    especially when I'm trying to obtain a species average.
    I tried to run the program on three different computers (laptops and
    desktop computers) with different version of windows (XP, Vista and 7),
I reduced the number of faces/triangles of my 3D models, but the problem
    remains.

    Does anyone know about this?

    Thanks a lot.

    Best,

    Aurélien

    --
    Post-doctoral Research Fellow
    The Leverhulme Centre for Human Evolutionary Studies
    Biological Anthropology Division, Department of Archaeology and
    Anthropology
    University of Cambridge
    Fitzwilliam Street
    Cambridge CB2 1QH
    United Kingdom
    --
    Chercheur associé
    UMR 6578 - Anthropologie Bioculturelle
    CNRS / Université de la Méditerranée /EFS
    Faculté de Médecine / Secteur Nord
    CS80011 Bd Pierre Dramard
    13344 MARSEILLE Cedex 15
    France


Reply via email to