This is from the Tivoli for MQ monitors help - For monitors which monitor resources and determine numeric charac- teristics:
never Monitor does not trigger a response. Greater than Triggers if the current resource value is greater than the specified value. To define the highest acceptable limit, enter a number in the text entry field. Less than Triggers if the current resource value is less than the speci- fied value. To define the lowest acceptable limit, enter a number in the text entry field. Equal to Triggers if the current resource value is equal to the speci- fied value. To define the threshold value, enter a number in the text entry field. Not equal to Triggers if the current resource value is not equal to the specified value. To define the threshold value, enter a number in the text entry field. Increases Beyond Triggers if the previous resource value is below the threshold specified in the text field, but the current value is above the specified threshold. To define the threshold value, enter a number in the text entry field. Decreases Below Triggers if the previous resource value is above the threshold specified in the text field, but the current value is below the specified threshold. To define the threshold value, enter a number in the text entry field. Increase of Checks the current value against the previous value and triggers if the difference is greater than or equal to the threshold specified in the text field. To define the thres- hold value, enter a number in the text entry field. % increase of Computes the percentage difference between the previous resource value and the current value and triggers if the per- centage difference is greater than or equal to the specified value. To define the threshold percentage increase value, enter a number in the text entry field. Outside range Triggers if the current value falls outside the specified range. To define the acceptable range, enter a lower and upper limit separated by a dash in the text entry field. Peter Heggie (315) 428 - 3193 -----Original Message----- From: Robert Broderick [mailto:[EMAIL PROTECTED] Sent: Wednesday, August 06, 2003 7:15 AM To: [EMAIL PROTECTED] Subject: Tivoli Monitoring Before I go down the merry road....... Does Tivoli allow the monitoring of Queue Depth with respect to it growing. Someone on a call indicated it only monitors events. I'm looking for something simular to what QPASA does, but in Tivoli. bobbee _________________________________________________________________ The new MSN 8: advanced junk mail protection and 2 months FREE* http://join.msn.com/?page=features/junkmail Instructions for managing your mailing list subscription are provided in the Listserv General Users Guide available at http://www.lsoft.com Archive: http://vm.akh-wien.ac.at/MQSeries.archive This e-mail and any files transmitted with it, are confidential to National Grid and are intended solely for the use of the individual or entity to whom they are addressed. If you have received this e-mail in error, please contact the National Grid USA Enterprise Support Center on 508-389-3375 or 315-428-6360. Instructions for managing your mailing list subscription are provided in the Listserv General Users Guide available at http://www.lsoft.com Archive: http://vm.akh-wien.ac.at/MQSeries.archive